Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Tech (Berl) ; 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38462974

RESUMO

OBJECTIVES: One main challenge for textile implants is to limit the foreign body reaction (FBR) and in particular the fibrosis development once the device is implanted. Fibrotic tissue in-growth depends on the fiber size, the pore size, and the organization of the fibrous construction. Basically, non-woven fibrous assemblies present a more favorable interface to biological tissues than do woven structures. However, they are mechanically less strong. In order to combine both strength and appropriate topography properties, the design of a hybrid fibrous construct was considered and discussed in this work. METHODS: Two polyethylene terephthalate (PET) weaves (satin and plain) were assembled with a non-woven PET mat, using an ultrasound welding process. RESULTS: The physical and mechanical properties of the construction as well as its ability to interact with the biological environment were then evaluated. In particular, the wettability of the obtained substrate as well as its ability to interact with mesenchymal stem cells (MSC) at 24 h (adhesion) and 72 h (proliferation) in vitro were studied. CONCLUSIONS: The results show that the non-woven layer helps limiting cell proliferation in the plain weave construction and promotes conversely proliferation in the satin construction.

2.
J Biomed Mater Res B Appl Biomater ; 109(10): 1512-1524, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33523550

RESUMO

Foreign Body Reaction (FBR) is a critical issue to be addressed when polyethylene terephthalate (PET) textile implants are considered in the medical field to treat pathologies involving hernia repair, revascularization strategies in arterial disease, and aneurysm or heart valve replacement. The natural porosity of textile materials tends to induce exaggerated tissue ingrowth which may prevent the implants from remaining flexible. The purpose of this study is to assess the influence of the textile topography of various woven substrates on the wetting properties of these substrates and on their in vitro interaction with mesenchymal stem cells (MSC) at 24 and 72 hr. The tests were performed both at yarn and fabric level under forced wetting and ingrowth conditions in order to replicate the mechanisms going on in vivo under blood pressure. Results demonstrate that cell proliferation is influenced by the textile wetting properties, which can be tuned at yarn and fabric level. In particular, it is shown that a satin weave obtained from porous spun yarn limits cell proliferation due to the high porosity of the yarn and the limited saturation index of the weave. Yarn and fabric saturation seems to play a predominant role in cell proliferation on textile substrates.


Assuntos
Materiais Biocompatíveis/química , Fibrose/metabolismo , Reação a Corpo Estranho/prevenção & controle , Próteses Valvulares Cardíacas , Polietilenotereftalatos/química , Tecidos Suporte/química , Adesão Celular , Proliferação de Células , Humanos , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/metabolismo , Porosidade , Propriedades de Superfície , Têxteis , Engenharia Tecidual , Agentes Molhantes/química
3.
J Mech Behav Biomed Mater ; 103: 103559, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31786509

RESUMO

OBJECTIVE: This study aims at assessing the global dynamic behavior, closing energy and turbulence characteristics of self-expandable textile (inclined and straight yarn) transcatheter aortic valves (TAV) versus bioprosthetic TAVs. METHODS: Two self-expandable textile TAVs one with inclined yarn textile and another with straight yarn textile leaflets were assessed in a pulse duplicator and compared with a self-expandable commercial bioprosthetic TAV under physiological pressure and flow. Particle Image Velocimetry and high-speed imaging were performed. Effective orifice areas (EOA), leakage fractions (LF), Pinwheeling indices (PI), closing energy (E), viscous shear stresses (VSS) and Reynolds shear stresses (RSS) were calculated. RESULTS: (a) EOAs and LFs were 2.27 ± 0.03 cm2, 31.7 ± 0.6%; 2.25 ± 0.08 cm2, 26.6 ± 0.7%; and 1.63 ± 0.01 cm2, 29.1 ± 1.25% for inclined textile, bioprosthetic and straight textile TAV respectively (p < 0.0001). (b) Following same order, PIs were significantly different going from 1.16 ± 0.21%, 8.48 ± 0.8% and 8.865 ± 0.58% with the exception of CoreValve and straight yarn valve (p = 0.37); (c) E is lowest for straight textile TAV (0.0024 ± 0.0017 J), followed by bioprosthetic valve (0.00259 ± 0.0011 J) and then 45° Oriented Yarn Valve (0.00334 ± 0.03 J) (d) At peak systole, the highest RSS distribution was with the Straight textile TAV reaching up to 330Pa. The bioprosthetic TAV shows the smallest range with RSS reaching around 230Pa and the inclined textile TAV up to 280Pa. VSS limits were comparable among the 3 valves ranging between 5.2Pa and 5.7Pa. CONCLUSION: Hemodynamic similarities were found between the textile self-expandable valves and the bioprosthetic valve. This study constitutes another step towards showing the potential that textile valves have to become an alternative for the biological ones.


Assuntos
Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica , Hemodinâmica , Desenho de Prótese , Têxteis
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...